In the UK it's usually called a tube plate, not a tube sheet. Same part: the drilled plate that holds every tube and separates shell side from tube side. We machine tube plates to your drawing in Mumbai and ship them to Felixstowe, Southampton or London Gateway.
Updated 28 Oct 2026
A tube plate (also written tubeplate) is what British drawings call a tube sheet. NPRO India machines tube plates to UK customer drawings, quotes against the BS EN or ASME material grade on the print, and ships to Felixstowe, Southampton or London Gateway. The exchanger maker remains responsible for UKCA or CE marking of the finished equipment.
UK enquiries mostly come from heat exchanger and process equipment fabricators, plus maintenance buyers at North Sea oil and gas operators, chemical plants on Teesside and elsewhere, and power stations.
Drawings arrive in two flavours. Some are designed to PD 5500 or BS EN 13445 with EN material grades such as 1.4404; others, often for oil and gas operators, follow ASME Section VIII with SA-grade materials. We quote against whichever your drawing uses and don't swap one for the other.
We use tube plate on this page because that's what UK engineers search for and write on their drawings. The rest of our site says tube sheet; it's the same part.
| What UK drawings call it | Tube plate / tubeplate |
| Design codes seen | PD 5500, BS EN 13445, ASME VIII |
| Regulation (GB) | Pressure Equipment (Safety) Regulations 2016 |
| Certificates | EN 10204 3.1 (3.2 on request) |
| Ports | Felixstowe, Southampton, London Gateway |
| Enquiries | +91 9594639793 · sales@nproindia.in |
If you're writing an enquiry or reading a quote from us, these are the terms that tend to cross between UK and US practice.
| UK term | US / ASME term | Note |
|---|---|---|
| Tube plate, tubeplate | Tubesheet | Identical part |
| Tube plate drilling | Tubesheet drilling | Drilling the tube hole pattern, often with grooving |
| Fixed tube plate | Fixed tubesheet | Welded to the shell at both ends |
| Floating head tube plate | Floating tubesheet | Free end moves with thermal expansion |
| Pass partition groove | Pass partition groove | Same; gasket groove for channel pass plates |
| 3.1 inspection certificate | Mill test report (MTR) | EN 10204 3.1 is the usual UK requirement |
In Great Britain, pressure equipment falls under the Pressure Equipment (Safety) Regulations 2016, with UKCA marking. Northern Ireland still follows the EU Pressure Equipment Directive. Rules on whether CE marking is accepted in GB have been extended more than once, so your exchanger maker or notified body confirms which mark applies to the finished unit.
The tube plate is a main pressure part, which is why EN 10204 3.1 material certificates are the normal ask. If your notified body requires 3.2 certificates, tell us at enquiry stage: 3.2 needs a third-party witness, and that has to be arranged before the material is tested, not after.
Design checks against PD 5500 or EN 13445 stay with your design engineer. We check the drawing can be machined: ligament width at your pitch, drilling depth on thick plates and groove details. The tolerance reference covers TEMA tolerances if your design uses them.
| Grade | EN number | Typical UK service |
|---|---|---|
| 316L stainless | 1.4404 | Chemical and process plant |
| 304L stainless | 1.4307 | Food, water and mild process duty |
| Duplex 2205 | 1.4462 | North Sea topsides, chloride-bearing cooling water |
| Super duplex 2507 | 1.4410 | Seawater service offshore |
| Titanium Grade 2 | 3.7035 | Seawater-cooled condensers |
| Copper-nickel 90/10 | CW352H | Coolers and condensers on seawater |
Full cross-references are in the grade equivalence table.
Background reading: the tube sheet (tube plate) guide and what drives tube plate thickness.
Most of the work in a tube plate is in the holes. UK drawings usually give the tube hole diameter and tolerance, the pitch and pattern, the number and size of grooves for expanded joints, and the face finish on gasket surfaces. On thick plates it's worth adding a tolerance at the exit face, because a long hole can drift as it's drilled.
If your design uses TEMA tolerances, our TEMA tolerance reference lists them. If it doesn't, the tolerances on your drawing apply and we work to those.
Since Brexit, UK imports need the importer's EORI number and the correct commodity code. Your customs broker confirms both; we supply the commercial invoice, packing list and certificate of origin they ask for.
Yes. Tube plate and tubeplate are the usual British terms; tube sheet and tubesheet are the US and ASME terms. It's the same drilled plate that anchors the tubes and separates the two fluids.
Yes, 3.1 certificates are the normal documentation for UK tube plates. If your notified body needs 3.2, tell us at enquiry stage so the third-party witness can be arranged before testing.
Yes. Your designer owns the PD 5500 or EN 13445 calculation; we machine to the drawing and check ligament, drilling depth and groove details before quoting.
The manufacturer of the finished heat exchanger. We supply the tube plate with its material and inspection records so they can complete their technical file.
Felixstowe, Southampton or London Gateway, or whichever port your forwarder nominates. Incoterms are agreed at order.
Drawing, EN or ASME grade, certificate type, quantity and UK delivery point. We review it before quoting.
Get an Export Quote →